
( Brand: Vevor Plush ), ( Manufacturer Part Number: FDGIR001 ), ( Type: Single Acting ), ( Application: Dump Truck, Unloading, Crane, Lifting Etc ), ( Power Source: Electric ), ( Material Of Tank: Plastic ), ( Rated Speed: 2850r/min ), ( Motor Power: 0.37-5.5kw ), ( Motor Voltage: Dc12-dv24 Ac220-380 ), ( Fuel Tank: 6l ), ( UPC: 278716903797 )
The FDGIR001 Single Acting Hydraulic Pump Dump Trailer Control Kit, manufactured by Vevor and with the item number 278716903797, is a crucial component for the efficient operation of your dump trailer. This kit is designed to replace worn-out or damaged parts, ensuring your trailer continues to function reliably.
The FDGIR001 includes a high-quality single acting hydraulic pump, specifically engineered for use in dump trailers. This pump is equipped with a robust piston and piston rod, ensuring a reliable and consistent flow of hydraulic fluid. The pump is also designed for easy installation, with clear mounting instructions included in the package.
The kit also includes a hydraulic cylinder, which is responsible for controlling the movement of the dump body. The cylinder is made from strong material, ensuring durability and resistance to corrosion. It is also equipped with a chromed rod for smooth operation and long-lasting performance.
The FDGIR001 Single Acting Hydraulic Pump Dump Trailer Control Kit is a comprehensive repair solution. It includes all the necessary components, such as hydraulic hoses, fittings, and mounting hardware, making it easy for you to replace worn-out parts and get your dump trailer back on the road.
In conclusion, the FDGIR001 Single Acting Hydraulic Pump Dump Trailer Control Kit from Vevor is a reliable and durable solution for maintaining the operation of your dump trailer. Its high-quality components, easy installation, and comprehensive package make it a smart choice for any trailer owner.
Pros of buying a FDGIR001 Single Acting Hydraulic Pump Dump Trailer Control Kit Repair Kit from Vevor (278716903797):1. Cost-effective solution: This kit is a budget-friendly option for repairing or replacing the hydraulic pump in a dump trailer.
2. Compatibility: The FDGIR001 kit is compatible with various dump trailer brands and models, making it a versatile choice for many users.
3. Easy installation: The kit comes with detailed instructions and all necessary components, making the installation process relatively straightforward.
Cons of buying a FDGIR001 Single Acting Hydraulic Pump Dump Trailer Control Kit Repair Kit from Vevor (278716903797):1. Quality concerns: Some users have reported issues with the quality of the components included in the kit, such as leaking seals or faulty valves.
2. Limited warranty: The kit comes with a limited warranty, which may not cover all potential issues that may arise during the use of the kit.
3. Potential compatibility issues: While the kit is advertised as being compatible with various dump trailer brands and models, it may not work with every single one. It's important to double-check the compatibility before making a purchase.
Conclusion:If you're looking for a budget-friendly solution for repairing or replacing the hydraulic pump in your dump trailer, the FDGIR001 Single Acting Hydraulic Pump Dump Trailer Control Kit Repair Kit from Vevor (278716903797) may be a good option to consider. However, it's important to keep in mind the potential quality concerns and limited warranty, and to double-check the kit's compatibility with your specific dump trailer before making a purchase.
Recommendation:If you're willing to spend a little more, consider looking into higher-quality kits from reputable manufacturers. They may offer better components, longer warranties, and more comprehensive compatibility information. Alternatively, you could also consider having a professional mechanic repair or replace the hydraulic pump for you, which may provide a more reliable and long-lasting solution.
Do not stick or write anything on the item itself its packaging.
Absolutely forbidden motor reverse rotation and oil-free idling. Tubing must also be clean.
5m removal cord and start solenoid price: precautions: the factory production of a hydraulic power unit when leaving factory, system pressure has been set.
In the installation and debugging for first time, we must keep internal fuel tank oil level, after a work cycle, should be made up, but not too full.
Please only write or place postage stickers on the outer packaging. Its high quality starter ensure long life and a fast starting each time.
Maintenance: we must keep the actuators, and pipeline cleaning, prevent dirt from entering system reduced lift platform controlled by electromagnetic unloading valve, falling speed is a built-in balancing valve.
After a year hours to replace new oil.
Relief setting for increased lifting power on a port. Working environment temperature high use hydraulic oil of viscosity,low with low viscosity.
When the gas tank hydraulic oil must be filtered, filtration precision is not lower than 25 microns. In actuators,without load, start the electric, short run test, check whether all parts smoothly, determine and correct after loading step by to normal operation.
Perfect replacement pump for 12vdc controlled hydraulic system designed horizontal mounting standard duty motor fluid choice determined by operating environment temperature material of tank: plastic displacement pump. Inching motor observe any abnormal phenomenon. 8ml r, applicable to all single power unit for 3, 6, 8, 10 quart.
Power unit can't filter the impurities inside hydraulic cylinder.
So the hydraulic cylinder internal must clean.
We must keep the tank oil level, after a work cycle, proper fill. Such as pump suction air will cause the damage of and seal hours after running hydraulic oil for first time to join, change new.
Connection for the first time, inching motor check direction, from back end, spin to counterclockwise.
Its widely used in sacker, Small and medium-sized lifting platform various industrial fields. If you want to change, the user according actual situation on their own through knob adjust system pressure regulating valve, but no more than nominal of.
Ac power motor shell must be reliable grounding, forbidden ground operation. Back-up manual unloading valve is used to power down.
Electrical and electromagnetic valve connection should pay special attention to the supply characteristics ac, dc voltage has same sign. The motor terminal box note waterproof, moisture proof. The motor is built to last, and tank has been specifically designed not crack leak under harsh conditions.